Power Station Sizing Calculator
For EIA’s 70 W most-used refrigerator average over eight hours, 8 × 70 ÷ 0.85 ≈ 658.8 Wh, which this calculator rounds up to 659 Wh. That energy budget does not replace the starting-watt check: Honda lists 192 W running and 1,200 W starting for an ENERGY STAR refrigerator or freezer.
Required Wh ≈ (sum of running watts × hours × quantity) ÷ inverter efficiency, then rounded up to a whole watt-hour. Starting, one at a time = running total + the largest extra start (start − run).
Default efficiency is 0.85, a planning assumption used on this site when a maker does not publish one. Do not add the EIA average and the Honda running watts as two fridge energy lines unless you really mean to count both.
Size energy and check starting watts
The default line is EIA’s 70 W refrigerator average for eight hours at 0.85 efficiency, which rounds up to 659 Wh. Add Honda start/run rows for the inverter check. This is an energy budget and a published-spec watt check, not a purchase recommendation or a lab test.
Your sizing estimate
Enter finite values of zero or more for quantity, watts, hours, and optional station figures. Efficiency must be greater than zero. Quantity must be a whole number.
- Required battery energy
- Check inputs
- Energy before rounding
- Check inputs
- Running watts, if on together
- Check inputs
- Starting, one at a time
- Check inputs
- Starting, all at once
- Check inputs
At least one selected row uses a running, typical, or Honda start/run figure with 24 hours of use. That treats the cited running or typical watts as continuous and can overstate the energy budget. Use a cycling average, a measured average, or the hours the load is actually on.
240 V load selected. A typical 120 V portable power station cannot feed that load. Enough watt-hours does not fix a voltage mismatch.
CPAP estimate: not medical advice or a UPS rating. Use your own manual and plan backup with your clinician.
Watt totals assume the selected loads can be on together, even when hours of use are lower. If starting watts are blank, they are treated as equal to running watts, so no extra start is invented. Required watt-hours are rounded up to a whole number, matching the battery runtime calculator.
Inputs stay in this page’s URL, not an account. Copying a link shares load names and numbers. Do not include private or medical details.
Worked example: 659 Wh, plus a 1,200 W start
EIA’s 2020 RECS Table CE5.3b gives the most-used refrigerator figure used by the default load: 617 kWh/year, or 617 ÷ 8,760 × 1,000 ≈ 70 W average.
- Energy at the fridge: 70 W × 8 h = 560 Wh.
- Energy at the battery: 560 ÷ 0.85 ≈ 658.8 Wh, rounded up to 659 Wh. The battery runtime calculator uses the same rounding when you ask for required capacity.
- Starting-watt check, from Honda: 192 W running and 1,200 W starting. If that fridge is the only load, one-at-a-time starting is 192 + (1,200 − 192) = 1,200 W.
Leave the Honda row’s hours at 0 if you only want that starting check beside the EIA energy line. If you instead use 192 W for eight hours, the energy total becomes 192 × 8 ÷ 0.85 ≈ 1,807 Wh, which is a different, more severe assumption, not the default example.
Optional published-spec comparisons use the 1 kWh-class capacities already cited on this site, such as 1,070 Wh, 1,024 Wh, 1,152 Wh, and 1,056 Wh. Those figures are published ratings, not usable-energy measurements and not recommendations.
Energy and starting watts are separate checks
A pack can have enough watt-hours and still fail to start a compressor, or start the compressor and run out of energy in a few hours. Use this calculator for both checks on the same list, or split the work: energy here or in the battery runtime tool, and a load-by-load watt check in the generator and power station wattage calculator.
The 0.85 factor is an assumption, not a measured efficiency for every station. Cold, aging, reserved capacity, and inverter overhead at low load all reduce what you can actually use. For a stricter runtime illustration that includes depth of discharge and a standby allowance, see the battery runtime calculator’s optional AC180-form check. Prefer the maker’s formula when it covers your load.
There are no affiliate links on this page today. There are no buy links on this page. See our affiliate disclosure.
Sources for presets and example stations
- US EIA 2020 RECS Table CE5.3b, revised March 2024. The 617 kWh/year most-used refrigerator figure behind the 70 W average.
- ENERGY STAR Certified Residential Refrigerators dataset and ENERGY STAR Certified Residential Freezers dataset. Certified annual-use figures used in those presets.
- Honda wattage estimation guide. Starting and running watts, including 1,200 W to start and 132–192 W to run for an ENERGY STAR refrigerator or freezer. The default running value is the high end of that range.
- ResMed AirSense 11 Americas user guide. Published CPAP power figures, not medical advice or a UPS rating.
- Example-station capacities and watt limits come from the same cited product pages already used on this site: Jackery Explorer 1000 v2, EcoFlow DELTA 2, BLUETTI AC180, and Anker SOLIX C1000. Those links are sources, not affiliate links.
Related calculators and guides
- Generator and power station wattage calculator: running and starting watts, including 240 V flags.
- Battery runtime calculator: hours from a pack’s watt-hours, or required Wh for a target duration.
- RV and van electrical planner: daily watt-hours and 12 V or 24 V amp-hours.
- Solar recharge calculator: an optimistic daily watt-hour ceiling from panel watts and peak sun hours.
- Appliance electricity cost calculator: kWh and bill cost at a rate you enter.
- What can a 1000 Wh power station run during an outage?
- Refrigerator runtime: average energy versus compressor starts.
- Sizing a power station for a CPAP overnight
Frequently asked questions
How many watt-hours do I need for eight hours on a refrigerator?
At EIA’s 70 W most-used refrigerator average and the default 0.85 efficiency, required watt-hours ≈ 8 × 70 ÷ 0.85 ≈ 658.8 Wh, which this calculator rounds up to 659 Wh. That is an energy budget, not a purchase recommendation and not a test of your fridge. The inverter must still handle the compressor start.
Why isn’t Honda’s 192 W running figure used for the default energy total?
Honda’s 192 W figure is a running-watt estimate while the compressor is on, not a day-long or eight-hour average. Using 192 W × 8 hours would overstate a typical cycling fridge. The default energy line uses EIA’s 70 W average. Add the Honda 192 W / 1,200 W row, with hours at 0 if you only want the starting-watt check.
If a published 1,000 Wh-class station shows PASS, will it run my loads?
Not necessarily. A PASS only means the published watt-hour capacity or watt limit is at least as large as the calculated need. Surge duration, voltage, temperature, battery age, reserved capacity, and the appliance itself still matter. The Anker SurgePad figure is a maker label, not automatically a motor-start rating. Check the nameplate and the station manual.