RV and Van Electrical Planner
For EIA’s 70 W most-used refrigerator average running all day through an inverter, 70 W × 24 h = 1,680 Wh at the load. With the site’s 0.85 planning efficiency, battery energy is 1,680 ÷ 0.85 ≈ 1,976.5 Wh, or about 164.7 Ah at 12 V. That is a daily energy budget, not a wiring plan or a test of a camper fridge.
Load Wh/day = watts × hours/day × quantity. Battery Wh/day ≈ AC load Wh/day ÷ inverter efficiency, plus DC load Wh/day. Ah/day = battery Wh/day ÷ bus volts.
Default efficiency is 0.85 and default bus voltage is 12 V. Honda running-watt rows are not day-long averages, so the planner starts those at 1 hour per day. Do not invent a van-specific wattage that is not in the cited tables.
Plan daily energy and a starting-watt check
Default bus voltage is 12 V. AC loads use the site’s 0.85 planning efficiency unless you change it. DC loads on the same bus do not use that inverter factor. This is a planning worksheet, not an electrical design or a battery-chemistry recommendation.
Your daily energy estimate
Enter finite values of zero or more for quantity, watts, hours, voltage, and efficiency. Efficiency and bus voltage must be greater than zero. Quantity must be a whole number.
- Energy at the loads
- Check inputs
- Battery energy per day
- Check inputs
- Battery amp-hours per day
- Check inputs
- Energy for the entered days
- Running watts, if on together
- Check inputs
- Starting, one at a time
- Check inputs
At least one selected row uses a running, typical, or label figure with 24 hours per day. That treats the cited running or typical watts as continuous and can overstate daily energy. Use a cycling average, a measured average, or the hours the load is actually on.
240 V load selected. A typical 12 V or 24 V van inverter and a typical 120 V receptacle cannot feed that load. Enough watt-hours does not fix a voltage mismatch.
CPAP estimate: not medical advice or a UPS rating. Use your own manual and plan backup with your clinician.
Watt totals assume the selected loads can be on together, even when hours per day are lower. Starting, one at a time uses a cited or entered start figure when one is present; if starting watts are blank, they are treated as equal to running watts, so no extra start is invented.
Inputs stay in this page’s URL, not an account. Copying a link shares load names and numbers. Do not include private or medical details.
Worked example: 1,680 Wh at the load
EIA’s 2020 RECS Table CE5.3b gives the most-used refrigerator figure used by the default load: 617 kWh/year, or 617 ÷ 8,760 × 1,000 ≈ 70 W average. Because that figure already spreads cycling over the day, 24 hours is the usual period input.
- Energy at the fridge: 70 W × 24 h = 1,680 Wh/day.
- Energy at the battery through an inverter: 1,680 ÷ 0.85 ≈ 1,976.5 Wh/day.
- At a 12 V bus: 1,976.5 ÷ 12 ≈ 164.7 Ah/day.
Honda’s ENERGY STAR fridge/freezer row is a different input: 192 W running and 1,200 W starting. That 192 W figure applies while the compressor is on. Multiplying it by 24 hours would overstate a typical day. Use it for the starting-watt check and for hours the compressor is actually running, or keep the EIA average for the daily energy line.
If you enter two days of autonomy, the optional total is daily battery watt-hours times two. The planner does not apply a depth-of-discharge, temperature, or lithium versus AGM factor, because those would be unsourced defaults.
What this worksheet does not size
A 12 V or 24 V amp-hour total is not a battery purchase recommendation. Available capacity depends on the bank you actually have, how far you discharge it, temperature, age, and the inverter’s behavior at low load. Wire gauge, fuses, charger current, and shore-power or solar recharge are outside this calculator.
The starting-watt line uses the same one-at-a-time method as the generator and power station wattage calculator: running total plus the largest extra start (start minus run) while the other loads stay on. Honda rows marked 240 V are flagged. A typical van inverter still has to start and run the load at the correct voltage.
There are no affiliate links on this page today. There are no buy links on this page. See our affiliate disclosure.
Sources for the cited loads
- US EIA 2020 RECS Table CE5.3b, revised March 2024. The 617 kWh/year most-used refrigerator figure behind the 70 W average.
- ENERGY STAR Certified Residential Refrigerators dataset. Certified refrigerator annual-use figures used in the refrigerator presets.
- ENERGY STAR Certified Residential Freezers dataset. Certified freezer annual-use figures used in the freezer presets.
- Honda wattage estimation guide. Starting and running watts for the Honda rows, including the 192 W / 1,200 W refrigerator figures. Those running watts are not day-long averages.
- ResMed AirSense 11 Americas user guide. Published CPAP power figures, not medical advice or a UPS rating.
Related calculators and guides
- Generator and power station wattage calculator: running and starting watts, including 240 V flags.
- Battery runtime calculator: hours from a pack’s watt-hours and an average load.
- Appliance electricity cost calculator: kWh and bill cost at a rate you enter.
- Solar recharge calculator: an optimistic daily watt-hour ceiling from panel watts and peak sun hours.
- What can a 1000 Wh power station run during an outage?
- Refrigerator runtime: average energy versus compressor starts.
- Sizing a power station for a CPAP overnight
Frequently asked questions
Why does an AC load use 0.85, and a DC load does not?
The 0.85 factor is this site’s planning assumption for inverter and conversion losses when a maker does not publish one. An AC appliance is assumed to be powered through an inverter, so battery watt-hours ≈ load watt-hours ÷ 0.85. A DC load already on the same 12 V or 24 V bus does not use that inverter factor. The efficiency input is editable. It is not a measured inverter curve.
Can I multiply Honda’s 192 W refrigerator running figure by 24 hours?
Not as a day-long energy budget. Honda’s 192 W figure is a running-watt estimate while the compressor is on, not a 24-hour average. The planner defaults those rows to 1 hour per day so the running watts are not treated as continuous. Use a cycling average, such as EIA’s 70 W figure, an EnergyGuide conversion, or a measured average, for hours-per-day energy.
Does this size a lithium or AGM bank, or tell me how to wire a van?
No. This worksheet estimates daily watt-hours and amp-hours from the loads and hours you enter, plus a running and one-at-a-time starting watt check. It does not choose battery chemistry, depth of discharge, wire gauge, fuse size, or charger settings, and it is not an electrical design.