Generator and Power Station Wattage Calculator

This tool adds Honda and other cited running and starting watts for the loads you select, then shows the running total and the starting total if the largest motor starts while the rest stay on. The default refrigerator is 192 W running and 1,200 W starting, from Honda’s wattage guide; we have not measured these appliances.

Select only the loads you plan to use at the same time. Replace editable defaults with figures from your appliance label or manual when you have them. Custom loads are your inputs, not Honda figures.

Choose the loads that will be on together

Start with one refrigerator, or change the list. Watts are per appliance; quantity multiplies each row. Editable defaults use the high end of a cited range.

Your wattage estimate

Running watts
192 W
Starting, one at a time
1,200 W
Starting, all at once
1,200 W

192 W running + 1,008 W extra start from ENERGY STAR refrigerator or freezer = 1,200 W.

One motor at a time is the default planning figure. All-at-once starting is a conservative overstatement unless those motors really start together.

Selections stay in this page's URL, not an account. A copied link includes custom names and watts. Do not enter private or medical details.

Kitchen and laundry
Kitchen and laundry appliances

Honda wattage estimation guide. Honda lists 1,200 W to start and 132–192 W to run. The default running value is the high end of that range so the running total is not understated. Edit it if you have a nameplate.

Honda wattage estimation guide. Honda’s input figure is 1,000 W starting and running. Cooking watts are not electrical input.

Honda wattage estimation guide. Honda’s input figure is 1,300 W starting and running.

Honda wattage estimation guide. Honda’s input figure is 1,500 W starting and running.

Honda wattage estimation guide.

Honda wattage estimation guide.

Honda wattage estimation guide.

Honda wattage estimation guide.

Honda wattage estimation guide.

Honda wattage estimation guide.

Heating and cooling
Heating and cooling appliances

Honda wattage estimation guide.

Honda tailgating / recreational wattage notes. Honda’s recreational figures, also cited on this site’s window-AC and space-heater guide. A 1,500 W household nameplate is a different input; add it as a custom load if that is what your heater says.

Honda wattage estimation guide.

Honda wattage estimation guide.

Honda wattage estimation guide.

Honda wattage estimation guide.

Honda wattage estimation guide.

Honda tailgating wattage notes. Honda estimates about 40 W running and 120 W starting.

Pumps and water
Pumps and water appliances

Honda wattage estimation guide.

Honda wattage estimation guide.

Honda wattage estimation guide.

Electronics and lights
Electronics and lights appliances

Honda wattage estimation guide.

Honda wattage estimation guide.

Honda wattage estimation guide.

Honda wattage estimation guide. Honda lists 200–250 W. The default is the high end. Prefer the watts on your charger.

Honda wattage estimation guide. Honda lists 600–800 W. The default is the high end.

Honda wattage estimation guide.

Honda wattage estimation guide. Honda lists 400–600 W. The default is the high end.

Honda wattage estimation guide. Honda lists 50–200 W. The default is the high end.

Honda wattage estimation guide. Honda says to use the watts indicated on the bulb (its example is a 60 W incandescent). Change the watts to match your label. A 10 W LED is a label example, not a Honda appliance row.

Medical example
Medical example appliances

ResMed AirSense 11 Americas user guide. Typical 56.1 W and peak 73.2 W with the official 65 W PSU, as published. Starting watts here use the published peak, which is not the same as a motor-start surge. Not medical advice and not a UPS rating. Use the figures in your own manual and plan backup with your clinician.

Your custom loads

User-entered values, not Honda figures. Enter electrical input watts from your label or manual, not cooking output or a bulb's equivalent brightness.

Compare your generator or power station (optional)

Use rated continuous AC output and the maker's surge/max rating. Passing the watt checks is not a guarantee of a motor start: surge duration, voltage and the appliance still matter.

Compare published power-station specs (optional)
Example stations, not recommendations

Published specs, not recommendations or tests. Select rows to compare watt limits above. These source links are not affiliate links.

1,070 Wh; 1,500 W continuous; 3,000 W instantaneous. Jackery Explorer 1000 V2 basic information.

1,024 Wh; 1,800 W continuous; 2,700 W surge. EcoFlow DELTA 2 US product page.

1,152 Wh; 1,800 W continuous; 2,700 W surge. BLUETTI AC180 US product page.

1,056 Wh; 1,800 W continuous; 2,400 W SurgePad. Anker SOLIX C1000 US product page.

SurgePad is a maker label, not automatically a motor-start rating. Do not count it as verified startup capacity.

Battery energy estimate (optional)

Hours ≈ Wh × 0.85 ÷ running watts. The 0.85 planning factor is an assumption for losses, not measured efficiency. Uses the running total, not starting watts. This is not fuel-generator runtime or a substitute for starting-watt checks. Cycling loads need measured average watts for a useful energy estimate.

Running watts and the two starting cases

Running watts describe a load while it operates. A motor can briefly need more power to start. Your generator or inverter has to cover the continuous load plus the largest startup that happens while other equipment stays on, as described in Honda’s sizing guidance and power-management guidance.

Running watts
Sum of (quantity × running watts) for every selected load you plan to have on at once.
Starting watts, one motor at a time
Running watts of the other selected loads + starting watts of the motor that is starting. Equivalently: running total + the largest (starting watts − running watts) among selected items. This is the default planning figure.
Starting watts, all at once
Sum of (quantity × starting watts). This is a conservative overstatement unless those motors really start together.

For several copies of one motor, the one-at-a-time case starts one copy while the others run. Honda’s informal example using the largest starting number alone does not replace this calculation: the other loads still need power during that start.

A refrigerator and a TV: 312 W running, 1,320 W starting

Honda’s table lists an ENERGY STAR refrigerator or freezer at 132 to 192 W running and 1,200 W starting, plus a 20-inch TV at 120 W starting and running. Use the high end of the fridge’s running range for this example.

  • Running total = 192 + 120 = 312 W.
  • Extra fridge startup = 1,200 − 192 = 1,008 W.
  • Fridge starting while the TV stays on = 1,200 + 120 = 1,320 W, or 312 + 1,008 = 1,320 W.

Adding all starting watts gives the same 1,320 W here because the TV has no extra starting demand in Honda’s table. Multiple motors can make the two starting cases differ.

Watts do not settle voltage or startup duration

A 240 V warning means Honda marks that appliance row as requiring 240 V, or you marked a custom load that way. A typical 120 V portable power station or a 120 V generator receptacle cannot feed it. Check the actual appliance and supply labels; enough watts do not change the voltage.

Compare running watts with the supply’s rated continuous output. Compare the one-at-a-time starting figure with its published surge or maximum output, then check how long that output is allowed and any motor-load limits. A numerical pass is not a tested compatibility claim. Anker’s SurgePad is a maker label, not automatically a motor-start rating. The optional station rows show published specs, not recommendations.

Battery energy is a separate check: hours ≈ battery Wh × 0.85 ÷ average running W. The 0.85 planning factor is a site assumption for usable energy and losses, not a measured efficiency. The calculator’s selected running total is a steady-load assumption; a cycling refrigerator’s average can be lower. This is a battery energy estimate, not fuel-generator runtime, and it does not replace starting-watt checks.

Plug loads into the supply, not a wall outlet

Do not backfeed building wiring through a wall receptacle. CPSC’s Portable Generator Hazards warns that generator backfeeding can electrocute utility workers and neighbors and bypass household circuit protection. A battery inverter does not make that connection safe. See backup power for renters and apartments for the site’s connection and generator-placement guidance.

These are estimates only, not a wiring plan. Follow equipment manuals and use a qualified electrician for any connection to building wiring. Fuel generators must not run indoors. If you select the CPAP example, its published peak is not a motor-start rating; this tool is not medical advice or a guarantee of uninterrupted therapy. Plan medical backup with your clinician and equipment provider.

There are no affiliate links on this page today. See our affiliate disclosure.

Sources for the inputs and limits

Each appliance row links its source. Optional station comparison rows link their makers’ published specifications. None of these figures is a measurement by this site.

Frequently asked questions

What is the difference between starting watts and running watts?

Running watts are the power a load needs while operating. Starting watts are a brief higher demand, often from a motor. Add all loads that will run together, then add the largest extra startup demand: that motor’s starting watts minus its running watts. Adding only the largest starting number leaves out the other loads that stay on.

Can a 1500 to 1800 W power station start a refrigerator?

On paper, Honda’s ENERGY STAR refrigerator example needs 1,200 W to start and up to 192 W to run. With its 120 W TV example still on, startup demand is 1,320 W. That is below a 1,500 to 1,800 W continuous rating, but it does not prove your fridge will start. Check your appliance’s startup demand, the station’s voltage, surge duration, and manual. We have not tested this combination.

What does a 240 V warning mean in this calculator?

The selected Honda row is marked as requiring 240 V, or you marked a custom load that way. A typical 120 V portable power station or a 120 V generator receptacle cannot supply that load, even if its watt rating is high enough. Check your appliance nameplate and the supply’s actual output voltage. A plug adapter does not convert 120 V to 240 V.