Power Station Battery Runtime Calculator

A 1000 Wh pack at 0.85 efficiency estimates to 12.1 hours on EIA’s 70 W most-used refrigerator average: 1000 × 0.85 ÷ 70 ≈ 12.1 hours. That assumes the inverter can start and run the fridge; we have not tested this combination.

Runtime (hours) ≈ battery capacity (Wh) × inverter efficiency ÷ load (W)

Default efficiency is 0.85, a planning assumption used on this site when a maker does not publish one. These are estimates from published inputs, not a lab test.

Estimate hours from your battery and load

Use the published battery capacity and average load for an AC-outlet estimate. This does not check startup, voltage, or continuous inverter limits.

Battery and load

Capacity and load must be greater than zero. Default efficiency is 0.85, a planning assumption used on this site when a maker does not publish one.

617 kWh/year ÷ 8,760 × 1,000 ≈ 70 W. This is a day-long average, not starting watts. EIA 2020 RECS Table CE5.3b, revised March 2024

Required capacity uses your efficiency input. Leave target duration blank to hide it.

Optional stricter check

BLUETTI’s AC180 formula: hours = Wh × DoD × η ÷ (load + self-consumption). Defaults are 0.90 DoD, 0.85 η, and a 15 W planning allowance, not a measured standby figure for your pack. Prefer the maker’s formula when it covers the load.

BLUETTI excludes inductive compressor loads such as refrigerators from this formula. For those loads, this is an arithmetic illustration, not a validated runtime prediction.

Compare published station capacities (optional)
Example capacities

Each row uses the same load and the fixed 0.85 planning efficiency, even if you edit your own efficiency above. These are capacity comparisons, not recommendations or compatibility checks. Opting into the stricter check adds that illustration too.

Jackery Explorer 1000 V2 basic information. Published capacity, not measured usable AC energy.

EcoFlow DELTA 2 US product page. Published capacity, not measured usable AC energy.

BLUETTI AC180 US product page. Published capacity, not measured usable AC energy.

Anker SOLIX C1000 US product page. Published capacity, not measured usable AC energy.

Your runtime estimate

Estimated runtime
Enable JavaScript

Estimates only, not a lab test. Temperature, battery age, inverter overhead, and actual load change the hours. Enough stored energy does not prove that the inverter can start or power the appliance.

Inputs stay in this page’s URL, not an account. Copying a link shares the numbers and selected presets. Do not include private or medical details.

The same 70 W load, three calculations

The 1000 Wh capacity is a worked example, not a measured usable-energy figure. The 70 W preset rounds EIA’s 617 kWh/year: 617 ÷ 8,760 × 1,000 ≈ 70 W.

  • Estimated runtime: 1000 × 0.85 ÷ 70 ≈ 12.1 hours.
  • Capacity needed for a target duration: Wh ≈ hours × load W ÷ 0.85. For eight hours: 8 × 70 ÷ 0.85 ≈ 659 Wh. The calculator uses your edited efficiency if you change it and rounds required capacity up to a whole Wh.
  • Optional stricter illustration: 1000 × 0.90 × 0.85 ÷ (70 + 15) ≈ 9.0 hours.

The stricter line uses BLUETTI’s published AC180 form: hours = Wh × DoD × η ÷ (load + self-consumption), with default DoD 0.90, η 0.85, and a 15 W planning allowance. The 15 W is not a measured standby figure for your pack. BLUETTI excludes inductive compressor loads such as refrigerators, so this fridge line illustrates arithmetic only. Prefer the maker’s formula when it covers the load.

The 1000 Wh outage guide works through the AC180 form, and the CPAP guide shows how overhead changes an overnight energy budget.

Average watts set hours; starting watts check the inverter

A compressor’s running watts apply while it is on. Its starting watts are a brief higher demand. Neither is automatically the cycling average that sets runtime. Use the generator and power station wattage calculator for the separate running and startup checks, and the refrigerator guide for the difference between these wattages.

Cycling loads need annual kWh or an energy meter over a useful period to get a useful average. Convert annual energy with average W ≈ annual kWh ÷ 8,760 × 1,000. Annual kWh already include cycling under the rating conditions; do not divide by a second guessed duty cycle. Heat, defrost, and door openings can change the actual outage load.

The 0.85 factor is an assumption, not an efficiency measurement for every station. Low loads can spend a larger share of energy on inverter overhead. Cold, aging, and reserved battery capacity also reduce available energy. A DC or USB path has different losses from the AC inverter modeled here.

Do not backfeed a wall outlet

Plug appliances into the station’s rated outlets. Do not feed building wiring through a wall receptacle. CPSC’s Portable Generator Hazards warns that backfeeding can electrocute utility workers and neighbors and bypass household protection. A battery inverter does not make that connection safe.

Any connection to building wiring needs an approved transfer arrangement and a qualified electrician. See backup power for renters and apartments for connection limits. CPAP estimates are not medical advice or a UPS rating; plan backup with your clinician and equipment provider.

There are no affiliate links on this page today. See our affiliate disclosure.

Sources for presets and limits

The load picker shows the source note for each preset. Optional station rows cite their published capacities, not our measurements. The LED preset is a label example, not a tested lamp.

Frequently asked questions

How long will a 1000 Wh battery run a refrigerator?

At EIA’s 70 W most-used refrigerator average and an assumed 0.85 conversion factor, 1000 × 0.85 ÷ 70 ≈ 12.1 hours. That is an energy estimate, not a test of your fridge. The inverter must also handle compressor starts. Use your EnergyGuide annual kWh or an energy-meter average instead of the preset when you have it.

How many watt-hours do I need for eight hours?

At a 70 W average load and the default 0.85 efficiency, required Wh ≈ 8 × 70 ÷ 0.85 ≈ 659 Wh. This is a first energy budget, not a purchase recommendation. Leave margin for battery age, temperature, inverter overhead, and a higher actual load. Changing the efficiency input changes the required capacity.

Why is the optional stricter runtime shorter?

BLUETTI’s published AC180 form includes depth of discharge and the station’s own consumption: hours = Wh × DoD × η ÷ (load + self-consumption). At the default illustration, 1000 × 0.90 × 0.85 ÷ (70 + 15) = 9.0 hours. The 15 W is a planning allowance, not a measured standby figure for your pack. BLUETTI excludes inductive compressor loads such as refrigerators from this formula. Prefer your maker’s formula when it covers your load.